Fiery Command WorkStation

Hide or show navigationPrevious topicNext topicSharePrintPDF

Open a large job

In some cases, a large job may not open or display correctly if Image Enhance Visual Editor (IEVE) is installed on the Fiery Server that also has a FACI kit installed. Increasing the hard disk space available on the Fiery Server may correct this problem.

  1. Close IEVE and Command WorkStation.
  2. Create a folder for the temporary files on the E: drive. Name the folder Temp.
  3. On the Windows Start menu, click Control Panel.
  4. In Control Panel, double-click System.
  5. In the System Properties dialog box, click the Advanced tab. Click Environment Variables.
  6. In the Environment Variables dialog box, at the top, select the TEMP variable. Click Edit.
  7. In the Edit User Variable dialog box, enter the path to the Temp folder you created in step 2. Click OK.
  8. Repeat steps 6-7 for the TMP variable. Use the same path as in step 7.
Note: The next time you open a large job, IEVE will use this temporary folder and the job should render correctly.