Compare reference and sample colors in Verifier

You can verify the color consistency of your jobs by printing out a control bar and measuring it against a selected reference. You can also verify a house standard by verifying saved measurement data against a selected reference.

The steps below are an example of how you can achieve ISO 12647-7 compliance. However, you can verify any suitable combination of sample data against a reference.

Before you begin:

  • Make sure that you have set up Verifier for color verification.

  • Verify by measurement only: Set up and connect your measuring device to the computer.

  • Verify by data comparison only: Make sure that saved measurement data is available.

  1. Start Verifier.
  2. For the first set of measurement values (reference), click Open, and do one of the following:
    • Verify by measurement: From the Fogra_MKCheck11 folder, load a Fogra characterization data set—for example, Fogra39.it8 (for ISOcoated_v2_eci.icc).

    • Verify by data comparison: Load the Ugra/Fogra media wedge measurement data.

  3. For the second set of measurement values (sample), do one of the following:
    • Verify by measurement: Click Measure, and measure the media wedge.

    • Verify by data comparison: Click Open. From the Fogra_MKCheck11 folder, load a Fogra characterization data set—for example, Fogra39.it8 (for ISOcoated_v2_eci.icc).

You can now review the verification results.