Edit the calibration target

The maximum densities of the calibration target (D-Max values) that is associated with a specific calibration setting are editable when you create the calibration setting. For each colorant (C, M, Y, and K), you can type a new value, or you can import a calibration target from a file.

The edited target data replaces the target data currently associated with this calibration setting when you apply the current measurement data.

Import the target data from a file if you have an existing profile and calibration target from another Fiery Server that you want to use on this Fiery Server. For best results, however, use profiles and calibration data that have been created specifically for this Fiery Server and its printer.

Even though you can edit the maximum density values, we recommend that you do so with caution. A calibration target represents the ideal values for calibration and should not be changed unnecessarily.

  1. After you have successfully measured the calibration page for the new calibration setting, click View Measurements.
  2. Do one of the following:
    • Type new values for the D-Max values under Target.

    • Click Import Target, browse to the file location, select the file, and click Open.

      Only files containing monotonic measurements are acceptable as imported targets.

  3. Continue creating the calibration setting.