Spot Pro optimizes one or
more selected spot colors for a given media or substrate and an output profile. Optimization
may reduce the color difference (∆E) and provide a better colorimetric match.
Before you begin, connect your measuring instrument to the computer.
Spot Pro supports all measurement instruments from FieryMeasure.
-
In Spot Pro, select one or
more spot colors.
-
Click Optimize.
-
Select the measurement device and specify the desired settings.
-
Click Next to the Job Properties
window.
-
Set the media or substrate source.
Note: Do not change the color settings.
-
Click Print to print a chart of the spot colors to be
optimized.
-
Follow the on-screen instructions to measure the chart.
-
Click Next.
Spot Pro
displays the achieved average ∆E and the maximum ∆E.
-
Click Iterate to repeat the optimization procedure until
no further optimization is possible. In the optimization table, click the best
set of results, and then click Finish to save your
optimization.