Calibrate with ColorCal
ColorCal allows you to calibrate the Fiery Server without the use of a measurement instrument. Instead, ColorCal uses the scanner of the copier/printer to measure density values.
With ColorCal, you can prepare the scanner for ColorCal before calibrating the Fiery Server, using the Color Control Patches and grayscale strips included in the customer media pack that comes with your Fiery Server. You also need the grayscale strip to calibrate the Fiery Server.
Some models of Fiery Server support preparation of the scanner even if the grayscale strip is missing. In this case, the Fiery Server uses the measurements from the previous calibration or, if the Fiery Server has never been calibrated, a default set of measurements. However, for best results, use the grayscale strip.
Scanner preparation is optional. We recommend that you prepare the scanner after maintenance or service, or whenever the copier/printer output has been altered.
For some models of Fiery Server, you must perform additional steps at the copier/printer. In this case, you can print an instruction page in Calibrator that describes the additional steps.
Print measurement page and prepare scanner
When you print the ColorCal measurement page, you can choose to prepare the scanner as well. You perform scanner measurement using the grayscale strip, Color Control Patches strip, and ColorCal Scanner Page.
The next step is to calibrate the Fiery Server.
Calibrate the Fiery server
You perform ColorCal calibration using the grayscale strip and the ColorCal measurement page.
For this procedure, you must have just printed the ColorCal measurement page in Calibrator and, optionally, prepared the scanner.
- In Calibrator, under Get Measurements, click Measure.
- Place the grayscale strip face down on the glass (platen) along the top edge of the glass so that it is centered along the top edge of the measurement page.
- Place the ColorCal measurement page face down over the grayscale strip, as indicated on the ColorCal measurement page. Make sure that the patches on the grayscale strip do not overlap the color patches. Close the platen glass cover, being careful not to move the grayscale strip and color measurement page.
- Click Continue to start the ColorCal measurement.
- Click OK to complete calibration.
- To apply the measurement data to the Fiery Server, click Apply.
- To close Calibrator, click Done.