Fiery Command WorkStation

Calibrator

Hide or show navigationPrevious topicNext topicSharePrintPDF

G7 gray balance measurement results

View the results of the G7 gray balance measurement.

  1. Review the G7 gray balance measurement results. The NPDC (Neutral Print Density Curve) is displayed separately for CMY (composite) and K (black). Gray balance is plotted as a*b*. In the table, the weighted average must be less than 1.5 to show as green.  The weighted maximum must be less than 3 to show as green.
  2. Click Correction Options to display the correction curve, and expose advanced options applied to the formation of the correction curves. You can choose to keep the defaults or change them.
  3. Click Iterate to print the patches with the G7 calibration curves to see if the results are passing.
  4. Click Back to discard your iteration measurements.
  5. If the results are acceptable, click Accept to continue the calibration process.