View test results

The Measurement Results window displays the pass/fail test results. Each test consists of multiple measurements.

Detailed test results show the value and result for each measurement included in the test. If the difference between the measured value and the expected value is greater than the specified tolerance for a specific test, the test fails.

You can open Verifier to view all the data used by Color Verification Assistant to generate the test results. The set of tolerance values (from the Preferences window) used for the test is also transferred to Verifier as the Fiery Color Verification Assistant preset. The two sets of colors that are compared in Verifier are called M1 and M2. The table below shows the contents of M1 and M2 for each test in Color Verification Assistant.

Test name M1 M2
CMYK Verification Data computed from CMYK source profile and output profile Measurements of CMYK patches on Simulated Color Spaces page
RGB Verification Data computed from RGB source profile and output profile Measurements of RGB patches on Simulated Color Spaces page
Output Profile Data extracted from output profile Measurements of patches on Fiery Printer Color Space page
Printer Consistency Measurements of patches on rotated page Measurements of patches on nonrotated page
Measurement Device First measurements of patches Second measurements of the same patches
  1. Click the Results link next to the test name to view detailed test results.
  2. In the detailed test results, click the link to Verifier to view the test data in Verifier.